_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
| Bromcresol Green, Endpoint |
ALMACENAMIENTO: Temp. Ambiente (RT)
listo para Usarse
Linealidad: 0.5-8.0 g/dL
Long. Onda: 630 nm
Valor Normal 3.5-5.3 g/dL |
CATALOGO
A7502-120 1 x 120 ml
A7502-500 1 x 500 ml
A7502-1L 1 x 1 L
Necesita Calibrador o Estandar |
Productos Relacionados
A7502-STD Albumin Standard
C7506-50 Chemistry Calibrator |
_____________________________________________________________________________________________________
 |
________________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
| naphthylphosphate, Kinetic |
ALMACENAMIENTO: 2-8°C
Estabilidad despues de reconstituir: 24 Hrs Temp. Amb.
14 Dias de 2-8°C
Linealidad: 40 U/L
Long. Onda: 405 nm
Valor Normal : Fosfatasa Ácida Total: 2.5-11.7 U/L
Fosfatasa Prostática Ácida: 0.2-3.5 U/L
|
CATALOGO
A7503-100
Reagent 10 x 10 ml
L-Tartrate 1 x 5 ml
Acetate Buffer 1 x 15 ml
|
|
_____________________________________________________________________________________________________
 |
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
| Alcohol Dehydrogenase, Endpoint |
ALMACENAMIENTO: 2-8°C
Estabilidad despues de reconstituir: 7 Dias 2-8°C
Linealidad: 0.4 g/dL
Long Onda: 340 nm
Valor Normal: <0.1g/dL
|
CATALOGO
A7504-39 6 x 6.5 ml
A7504-150 10 x 15 ml
Requiere Standard
|
Productos Relacionados
A7504-STD Alcohol Standard
A7504-CTL Ammonia/Alcohol Control Set |
_____________________________________________________________________________________________________
 |
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
| p-NPP, Kinetic |
ALMACENAMIENTO: 2-8°C
Estabilidad despues de reconstituir: 7 Dias a Temp Ambiente y 60 Dias de 2-8°C
Linealidad: 800 U/L
Long. Onda: 405 nm
Valor Normal: Adultos 35-123 U/L
Niños siempre tienen un Valor Alto
|
CATALOGO
A7505-150 10 x 15 ml
A7505-300 20 x 15 ml
A7505-400 8 x 50 ml
A7505-1L 4 x 250 ml
|
|
_____________________________________________________________________________________________________
 |
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
| p-NPP, Kinetic |
ALMACENAMIENTO: 2-8°C
Estabilidad despues de reconstituir: Listo para Usarse
Linealidad: 0-1000 U/L
Long. Onda: 405 nm
Valor Normal: Adults 35-123 U/L
Niños siempre tienen un Valor Alto
|
CATALOGO
A7516-150 1 x 120 ml (R1)
1 x 30 ml (R2)
A7516-450 3 x 120 ml (R1)
1 x 90 ml (R2)
A7516-625 1 x 500 ml (R1)
|
|
_____________________________________________________________________________________________________
 |
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
| Optimized Tris Buffer, Kinetic |
ALMACENAMIENTO: 2-8°C
Estabilidad despues de reconstituir: 48 Horas temperatura Ambiente
30 Dias de 2-8°C
Linealidad: 500 U/L
Long. Onda: 340 nm
Valor Normal: Arriba de 38 U/L
|
CATALOGO
A7525-75 5 x 15 ml
A7525-150 10 x 15 ml
A7525-300 20 x 15 ml
A7525-400 8 x 50 ml
A7525-1L 4 x 250 ml
|
|
_____________________________________________________________________________________________________
 |
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
| Modified IFCC, Kinetic |
ALMACENAMIENTO: 2-8°C
Estabilidad despues de reconstituir: Listo para usarse
Linealidad: 0-500 U/L
Long. Onda: 340 nm
Valor Normal: 4 a 36 U/L
|
CATALOGO
A7526-150 1 x 120 ml (R1)
1 x 30 ml (R2)
A7526-450 3 x 120 ml (R1)
1 x 90 ml (R2)
A7526-625 1 x 500 ml (R1)
1 x 125 ml (R2)
|
|
_____________________________________________________________________________________________________
 |
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
| Ketoglutarate, Endpoint |
ALMACENAMIENTO: 2-8°C
Estabilidad despues de reconstituir: 15 Dias de 2-8°C
Linealidad: 600 umol/L
Long. Onda: 340 nm
Valor Normal: 11-35 umol/L
|
CATALOGO
A7553-34 Substrate 4 x 6.5 ml
Enzyme 4 x 2 ml
A7553-85 Substrate 10 x 6.5 ml
Enzyme 10 x 2 ml
Requiere Standard
|
Productos Relacionados
A7553-STD100 Ammonia Standard
A7553-STD500 Ammonia Standard
A7504-CTL Ammonia/Alcohol Control Set |
_____________________________________________________________________________________________________
 |
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
| Optimized Tris Buffer, Kinetic |
ALMACENAMIENTO: 2-8°C
Estabilidad despues de reconstituir: 48 Horas temperatura Ambiente
30 Dias de 2-8°C
Linealidad: 500 U/L
Long. Onda: 340 nm
Valor Normal: Arriba de 40 U/L
|
CATALOGO
A7560-75 5 x 15 ml
A7560-150 10 x 15 ml
A7560-300 20 x 15 ml
A7560-400 8 x 50 ml
A7560-1L 4 x 250 ml
|
|
_____________________________________________________________________________________________________
 |
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
| Modified IFCC, Kinetic |
ALMACENAMIENTO: 2-8°C
Estabilidad despues de reconstituir: Listo para usarse
Linealidad: 0-500 U/L
Long. Onda: 340 nm
Valor Normal:5-34 U/L
|
CATALOGO
A7561-150 1 x 120 ml (R1)
1 x 30 ml (R2)
A7561-450 3 x 120 ml (R1)
1 x 90 ml (R2)
A7561-625 1 x 500 ml (R1)
1 x 125 ml (R2)
|
|
_____________________________________________________________________________________________________
 |
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
| CNPG3, Kinetic |
ALMACENAMIENTO: 2-8°C
Estabilidad despues de reconstituir: Listo para usarse
Linealidad: 0-2,000 U/L
Long. Onda: 405 nm
Valor Normal: 25-125 U/L
|
CATALOGO
A7564-60 2 x 30 ml
A7564-120 4 x 30 ml
A7564-480 4 x 120 ml
A7564-1L 1 x 1 L
|
|
_____________________________________________________________________________________________________
 |
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
| Immunoturbidimetric |
ALMACENAMIENTO: 2-8°C
Estabilidad despues de reconstituir: Listo para usarse
Linealidad:3-250 mg/dL
Long. Onda: 340 nm
Valor Normal:
Mujer: 60-150 mg/dL
Hombre: 63-152 mg/dL
|
CATALOGO
A7588-150 1 x 120 ml (R1)
1 x 30 ml (R2)
Requiere Calibrador
|
Productos Relacionados
A7548-CAL Apolipoprotein A1/B Calibrator Set
L7580-18 Lipid Control Set |
_____________________________________________________________________________________________________
 |
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
| Immunoturbidimetric |
ALMACENAMIENTO: 2-8°C
Estabilidad despues de reconstituir: Listo para usarse
Linealidad: 2-250 mg/dL
Long. Onda: 340 nm
Valor Normal:
Mujer: 115-206 mg/dL
Hombre: 107-187 mg/dL
|
CATALOGO
A7544-150 1 x 120 ml (R1)
1 x 30 ml (R2)
Requiere Calibrador
|
Productos Relacionados
A7548-CAL Apolipoprotein A1/B Calibrator Set
L7580-18 Lipid Control Set |
_____________________________________________________________________________________________________
 |
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
Diazo, Endpoint
|
ALMACENAMIENTO: Temperatura Ambiente (RT)
Estabilidad despues de reconstituir: Listo para usarse
Linealidad: 20 mg/dL
Long. Onda: 550 nm
Valor Normal: 0-0.5 mg/dL
|
CATALOGO
B7538-120 Reagent 1 x 120 ml
Nitrite 1 x 15 ml
B7538-500 Reage n t 1 x 500 ml
Nitrite 1 x 15 ml
B7538-1L Reagent 1 x 1 L
Nitrite 1 x 15 ml
Requiere Calibrador
|
Productos Relacionados
B7538-CAL Bilirubin Calibrator
C7506-50 Chemistry Calibrator |
_____________________________________________________________________________________________________
 |
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
Walters & Gerarde, Endpoint |
ALMACENAMIENTO: 2-8°C
Estabilidad despues de reconstituir: Listo para usarse
Linealidad: 20 mg/dL
Long. Onda: 550 nm
Valor Normal: 0.2-1.2 mg/dL
|
CATALOGO
B7576-120 Reagent 1 x 120 ml
Nitrite 1 x 15 ml
B7576-500 Reagent 1 x 500 ml
Nitrite 1 x 15 ml
B7576-1L Reagent 1 x 1 L
Nitrite 1 x 15 ml
Requiere Calibrador |
Productos Relacionados
B7538-CAL Bilirubin Calibrator
C7506-50 Chemistry Calibrator |
_____________________________________________________________________________________________________
 |
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
Urease/GLD, Initial Rate |
ALMACENAMIENTO: 2-8°C
Estabilidad despues de reconstituir: 48 Horas temperatura Ambiente (RT)
30 Dias 2-8°C
Linealidad: 80 mg/dL
Long. Onda: 340 nm
Valor Normal: 7-18 mg/dL
|
CATALOGO
B7550-75 5 x 15 ml
B7550-150 10 x 15 ml
B7550-300 20 x 15 ml
B7550-400 8 x 50 ml
B7550-1L 4 x 250 ml
Requiere Calibrador y Standard |
Productos Relacionados
B7550-STD BUN Standard
C7506-50 Chemistry Calibrator |
_____________________________________________________________________________________________________
 |
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
Berthelot, Endpoint |
ALMACENAMIENTO: 2-8°C
Estabilidad despues de reconstituir: Listo para usarse
Linealidad: 70 mg/dL
Long. Onda: 630 nm
Valor Normal: 7-18 mg/dL
|
CATALOGO
B7551-120 120 test
Enzyme 1 x 60 ml
Color 1 x 60 ml
Base 1 x 240 ml
Standard 1 x 4 ml
|
Productos Relacionados
B7550-STD BUN Standard |
_____________________________________________________________________________________________________
 |
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
Berthelot, Endpoint |
ALMACENAMIENTO: 2-8°C
Estabilidad despues de reconstituir: Listo para usarse
Linealidad: 70 mg/dL
Long. Onda: 630 nm
Valor Normal: 7-18 mg/dL
|
CATALOGO
B7551-120 120 test
Enzyme 1 x 60 ml
Color 1 x 60 ml
Base 1 x 240 ml
Standard 1 x 4 ml
|
Productos Relacionados
B7550-STD BUN Standard |
_____________________________________________________________________________________________________
 |
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
Urease/GLD, Initial Rate |
ALMACENAMIENTO: 2-8°C
Estabilidad despues de reconstituir: Listo para usarse
Linealidad: 0-150 mg/dL
Long. Onda: 340 nm
Valor Normal: 7-18 mg/dL
|
CATALOGO
B7552-150 1 x 120 ml (R1)
1 x 30 ml (R2)
B7552-450 3 x 120 ml (R1)
1 x 90 ml (R2)
B7552-625 1 x 500 ml (R1)
1 x 125 ml (R2)
Requiere Calibrador y Standard |
Productos Relacionados
B7550-STD BUN Standard
C7506-50 Chemistry Calibrator |
_____________________________________________________________________________________________________
 |
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
Mercuric Thiocyanate, Endpoint |
ALMACENAMIENTO:Temperatura Ambiente (RT)
Estabilidad despues de reconstituir: Listo para usarse
Linealidad: 80-120 mEq/L
Long. Onda: 480 nm
Valor Normal: 98-106 mEq/L
|
CATALOGO
C7501-120 Reagent 1 x 120 ml
Blank 1 x 15 ml
C7501-500 Reagent 1 x 500 ml
Blank 1 x 30 ml
C7501-1L Reagent 1 x 1 L
Blank 2 x 30 ml
Requiere Calibrador y Standard |
Productos Relacionados
C7501-STD Chloride Standard
C7506-50 Chemistry Calibrator |
_____________________________________________________________________________________________________
 |
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
Cresolphthalein Complexone, Endpoint |
ALMACENAMIENTO: 2-8°C
Estabilidad despues de reconstituir: Listo para usarse
Linealidad: 20 mg/dL
Long. Onda: 570 nm
Valor Normal: 8.5-10.5 mg/dL
|
CATALOGO
C7503-120 Color 2 x 30 ml
Buffer 2 x 30 ml
C7503-480 Color 2 x 120 ml
Buffer 2 x 120 ml
Requiere Calibrador y Standard |
Productos Relacionados
C7503-STD Calcium Standard
C7506-50 Chemistry Calibrator |
_____________________________________________________________________________________________________
 |
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
PEPC, Initial Rate |
ALMACENAMIENTO: 2-8°C
Estabilidad despues de reconstituir: 24 Horas a Temp. Amb. (RT) y
14 Dias 2-8°C
Linealidad: 40 mmol/L
Long. Onda: 340 nm
Valor Normal: 23-34 mmol/L
|
CATALOGO
C7504-110 Reagent 10 x 11 ml
Diluent 1 x 120 ml
C7504-1L Reagent 4 x 250 ml
Diluent 1 x 1 L
Requiere Calibrador y Standard |
Productos Relacionados
C7504-STD Carbon Dioxide Standard
C7506-50 Chemistry Calibrator |
_____________________________________________________________________________________________________
 |
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
Cresolphthalein Complexone, Endpoint |
ALMACENAMIENTO: 2-8°C
Estabilidad despues de reconstituir: 5 Dias a Temp. Amb. (RT) y
30 Dias 2-8°C
Linealidad: 20 mg/dL
Long. Onda: 570 nm
Valor Normal: 8.5-10.4 mg/dL
|
CATALOGO
C7508-300 20 x 15 ml
C7508-400 8 x 50 ml
Requiere Calibrador y Standard |
Productos Relacionados
C7503-STD Calcium Standard
C7506-50 Chemistry Calibrator |
_____________________________________________________________________________________________________
 |
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
Enzymatic, Endpoint |
ALMACENAMIENTO: 2-8°C
Estabilidad despues de reconstituir: 60 Dias 2-8°C
Linealidad:500 mg/dL
Long. Onda: 520 nm
Valor Normal:Desirable Cholesterol: <200 mg/dL
Borderline-High Cholesterol: 200-239 mg/dL
High Cholesterol: >240 mg/dL
|
CATALOGO
C7509-75 5 x 15 ml
C7509-400 8 x 50 ml
C7509-1L 4 x 250 ml
C7509-2L 4 x 500 ml
Requiere Calibrador y Standard
|
Productos Relacionados
C7509-STD Cholesterol Standard
C7506-50 Chemistry Calibrator
L7580-18 Lipid Control Set |
_____________________________________________________________________________________________________
 |
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
Enzymatic, Endpoint |
ALMACENAMIENTO: 2-8°C
Estabilidad despues de reconstituir: Listo para Usar
Linealidad:700 mg/dL
Long. Onda:500 nm
Valor Normal:Desirable Cholesterol: <200 mg/dL
Borderline-High Cholesterol: 200-239 mg/dL
High Cholesterol: >240 mg/dL
|
CATALOGO
C7510-120 1 x 120 ml
C7510-500 1 x 500 ml
C7510-1L 1 x 1 L
Requiere Calibrador y Standard |
Productos Relacionados
C7509-STD Cholesterol Standard
C7506-50 Chemistry Calibrator
L7580-18 Lipid Control Set |
_____________________________________________________________________________________________________
 |
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
CK-NAC, Kinetic |
ALMACENAMIENTO: 2-8°C
Estabilidad despues de reconstituir: 24 Horas Temperatura Ambiente (RT)
30 Dias 2-8°C
Linealidad:1,500 U/L
Long. Onda:340 nm
Valor Normal:
Hombres: Arriva de 160 U/L
Mujeres: Arriva de130 U/L
|
CATALOGO
C7512-39 6 x 6.5 ml
C7512-120 20 x 6.5 ml
C7512-300 20 x 15 ml
C7512-400 8 x 50 ml
C7512-1L 4 x 250 ml
|
|
_____________________________________________________________________________________________________
 |
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
CK-NAC, Kinetic |
ALMACENAMIENTO: 2-8°C
Estabilidad despues de reconstituir: Listo para usarse
Linealidad:1,500 U/L
Long. Onda:340 nm
Valor Normal:
Hombres: Arriva de 160 U/L
Mujeres: Arriva de130 U/L
|
CATALOGO
C7522-150 1 x 120 ml (R1)
1 x 30 ml (R2)
C7522-450 3 x 120 ml (R1)
1 x 90 ml (R2)
C7522-625 1 x 500 ml (R1)
1 x 125 ml (R2)
|
|
_____________________________________________________________________________________________________

|
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
Arsenazo III, Endpoint |
ALMACENAMIENTO: Temperatura Amb. (RT)
Estabilidad despues de reconstituir: Listo para usarse
Linealidad: 0-15 mg/dL
Long. Onda: 650 nm
Valor Normal: 8.5-10.4 mg/dL
|
CATALOGO
C7529-120 1 x 120 ml
C7529-500 1 x 500 ml
C7529-1L 1 x 1 L
Requiere Calibrador y Standard
|
Productos Relacionados
C7503-STD Calcium Standard
C7506-50 Chemistry Calibrator |
_____________________________________________________________________________________________________

|
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
Modified Jaffe, Initial Rate |
ALMACENAMIENTO: Temperatura Amb. (RT)
Estabilidad despues de reconstituir: Listo para usarse
Linealidad: 25 mg/dL
Long. Onda: 510 nm
Valor Normal: 0.40-1.40 mg/dL
|
CATALOGO
C7539-150 1 x 120 ml (R1)
1 x 30 ml (R2)
C7539-625 1 x 500 ml (R1)
1 x 125 ml (R2)
C7539-1250
1 x 250 ml (R2)
|
Productos Relacionados
C7513-STD Creatinine Standard
C7506-50 Chemistry Calibrator
|
_____________________________________________________________________________________________________

|
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
Immunoinhibition, Kinetic |
ALMACENAMIENTO: 2-8°C
Estabilidad despues de reconstituir:24 Horas Temp. Amb. (RT9
6 Dias 2-8°C
Linealidad: 2,000 U/L
Long. Onda: 340 nm
Valor Normal: 0-22 U/L |
CATALOGO
C7562-26 Reagent 4 x 6.5 ml
Diluent 1 x 30 ml
C7562-65 Reagent 10 x 6.5 ml
Diluent 1 x 75 ml
C7562-150 Reagent 10 x 15 ml
Diluent 2 x 75 ml |
Productos Relacionados
C7562-12 CK-MB Controls |
_____________________________________________________________________________________________________

|
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
Immunoturbidimetric |
ALMACENAMIENTO: 2-8°C
Estabilidad despues de reconstituir: Listo para usarse
Linealidad: 0.1-3.20.0 mg/dL
Long. Onda: 570 nm
Valor Normal: 3.0 mg/dL |
CATALOGO
C7568-40 R1 Buffer 1 x 20 ml
R2 Antibody 1 x 20 ml
C7568-100 R1 Bu ffer 1 x 50 ml
R2 Antibody 1 x 50 ml |
Productos Relacionados
C7568-CAL CRP Calibrator Set
C7568-CTL CRP Control Set |
_____________________________________________________________________________________________________

|
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
Nitroblue Tetrazolium |
ALMACENAMIENTO: 2-8°C
Estabilidad despues de reconstituir: 7 Dias Temp. Amb. (RT)
30 Dias 2-8°C
Linealidad: 8.5 mmol/L
Long. Onda: 550 nm
Valor Normal: 1.61-2.68 mmol/L
|
CATALOGO
F7546-110 Substrate 10 x 11 ml
Buffer 1 x 120 ml
Calibrator 1 x 2 ml
Requiere Calibrador |
Productos Relacionados
F7546-CAL Fructosamine Calibrator
F7546-CTL Fructosamine Control Set |
_____________________________________________________________________________________________________

|
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
Hexokinase/G6PD, Endpoint |
ALMACENAMIENTO: 2-8°C
Estabilidad despues de reconstituir: Listo para usarse
Linealidad: 500 mg/dL
Long. Onda: 340 nm
Valor Normal: 65-110 mg/dL |
CATALOGO
G7517-120 1 x 120 ml
G7517-500 1 x 500 ml
G7517-1L 1 x 1 L
Requiere Calibrador y Standard |
Productos Relacionados
G7518-STD Glucose Standard
C7506-50 Chemistry Calibrator |
_____________________________________________________________________________________________________

|
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
Hexokinase/G6PD, Endpoint |
ALMACENAMIENTO: 2-8°C
Estabilidad despues de reconstituir: 5 Dias Temperatura Amb. (RT)
60 Dias 2-8°C
Linealidad: 600 mg/dL
Long. Onda: 340 nm
Valor Normal: 65-110 mg/dL |
CATALOGO
G7518-150 10 x 15 ml
G7518-300 20 x 15 ml
G7518-400 8 x 50 ml
G7518-1L 4 x 250 ml
Requiere Calibrador y Standard |
Productos Relacionados
G7518-STD Glucose Standard
C7506-50 Chemistry Calibrator |
_____________________________________________________________________________________________________

|
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
Oxidase/Trinder, Endpoint |
ALMACENAMIENTO: 2-8°C
Estabilidad despues de reconstituir: 30 Dias 2-8°C
Linealidad:500 mg/dL
Long. Onda: 500 nm
Valor Normal: 70-105 mg/dL |
CATALOGO
G7519-500 5 x 100 ml
G7519-1L 5 x 200 ml
G7519-5L 5 x 1 L
Requiere Calibrador y Standard |
Productos Relacionados
G7518-STD Glucose Standard
C7506-50 Chemistry Calibrator |
_____________________________________________________________________________________________________

|
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
Oxidase/Trinder, Endpoint |
ALMACENAMIENTO: 2-8°C
Estabilidad despues de reconstituir: Listo para Usarse
Linealidad:500 mg/dL
Long. Onda: 500 nm
Valor Normal: 70-105 mg/dL |
CATALOGO
G7521-120 1 x 120 ml
G7521-500 1 x 500 ml
G7521-1L 1 x 1 L
Requiere Calibrador y Standard |
Productos Relacionados
G7518-STD Glucose Standard
C7506-50 Chemistry Calibrator |
_____________________________________________________________________________________________________

|
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
Cation-Exchange Resin |
ALMACENAMIENTO: Temperatura Amb.
Estabilidad despues de reconstituir: Listo para Usarse
Linealidad:4.0-20%
Long. Onda: 415 nm
Valor Normal: 6.0-8.3%
|
CATALOGO
G7540-40 40 test
Resin 1 x 120 ml
Lysing 1 x 30 ml
Serum Separators 40
G7540-80 80 test
Resin 1 x 120 ml
Lysin 1 x 30 ml
Serum Separators 80
Requiere Standard |
Productos Relacionados
G7540-STD Glycohemoglobin Standard
G7540-2 Glycohemoglobin Controls |
_____________________________________________________________________________________________________

|
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
Modified Szasz, Kinetic |
ALMACENAMIENTO: 2-8°C
Estabilidad despues de reconstituir: 21 Dias 2-8°C
Linealidad:1000 U/L
Long. Onda: 405 nm
Valor Normal:
Hombre: 9-54 U/L
Mujer: 8-35 U/L
|
CATALOGO
G7570-100 10 x 10 ml
G7570-400 8 x 50 ml
G7570-1L 4 x 250 ml
|
|
_____________________________________________________________________________________________________

|
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
Modified Szasz, Kinetic |
ALMACENAMIENTO: 2-8°C
Estabilidad despues de reconstituir: Listo para usarse
Linealidad: 0-800 U/L
Long. Onda: 405 nm
Valor Normal: 8-54 U/L
|
CATALOGO
G7571-150 1 x 120 ml (R1)
1 x 30 ml (R2)
G7571-450 3 x 120 ml (R1)
1 x 90 ml (R2)
G7571-625 1 x 500 ml (R1)
1 x 125 ml (R2)
|
|
_____________________________________________________________________________________________________

|
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
Glucose-6-Phosphate, Kinetic |
ALMACENAMIENTO: 2-8°C
Estabilidad despues de reconstituir: 8 Horas Temperatura Ambiente (RT)
5 Diass 2-8°C
Linealidad: 21.0 U/g Hb
Long. Onda: 340 nm
Valor Normal: 12.1±2.09 U/g Hb |
CATALOGO
G7583-180 10 x 6 ml (R1)
1 x 120 ml (R2)
|
Productos Relacionados
G7583-LYS G6PD Lyse Reagent 100ml
G7583-CTL G6PD Control Set |
_____________________________________________________________________________________________________

|
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
Glucose-6-Phosphate, Indophenol |
ALMACENAMIENTO: 2-8°C
Estabilidad despues de reconstituir: 24 horas
|
CATALOGO
G7584-105 Reagent 7 x 15 ml
Buffer 1 x 120 ml
R
|
Productos Relacionados
G7584-CTL
G7584-MO Mineral Oil 500ml
G6PD Control Set |
_____________________________________________________________________________________________________

|
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
Cyanmethemoglobin, Endpoint |
ALMACENAMIENTO: Temp.Ambiente
Estabilidad despues de reconstituir: Listo para Usarse
Linealidad: 20.0 g/dL
Long. Onda: 540 nm
Valor Normal:
Hombres: 13.0-18.0 g/dL
Mujeres: 11.0-16.0 g/dL
Niños: 10.0-14.0 g/dL
Recien Nacidos: 14.0-23.0 g/dL |
CATALOGO
H7504-120 1 x 120 ml
H7504-500 1 x 500 ml
Requiere Standard
|
Productos Relacionados
H7506-STD Hemoglobin Standard
H7506-6 Hemoglobin Controls |
_____________________________________________________________________________________________________

|
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
Mg++/Dextran Sulfate (MW=50,000) Precipitating Reagent |
ALMACENAMIENTO: 2-8°C
Estabilidad despues de reconstituir: 90 Dias 2-8°C
Long. Onda: 520 nm
Valor Normal: 27-98 mg/dL
|
CATALOGO
H7507-25 5 x 5 ml
H7507-80 8 x 10 ml
Requiere Standard / Calibrador
|
Productos Relacionados
H7512-STD HDL Standard
C7574-50 Cholesterol Calibrator
C7509 Cholesterol Reagent
C7510 Cholesterol Liquid Reagent
L7580-18 Lipid Control Set |
_____________________________________________________________________________________________________

|
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
PEG (Polyethylene Glycol) Precipitating Reagent |
ALMACENAMIENTO: Temperatura Amb.
Estabilidad despues de reconstituir: Listo para Usarse
Long. Onda: 520 nm
Valor Normal: 30-75 mg/dL
|
CATALOGO
H7511-60 2 x 30 ml
Requiere Standard / Calibrador
|
Productos Relacionados
H7512-STD HDL Standard
C7574-50 Cholesterol Calibrator
C7509 Cholesterol Reagent
C7510 Cholesterol Liquid Reagent
L7580-18 Lipid Control Set |
_____________________________________________________________________________________________________

|
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
Immunoturbidmetric |
ALMACENAMIENTO: 02-8°C
Estabilidad despues de reconstituir: Listo para Usarse
Linealidad:2.0-16.0% mg/dl
Long. Onda: 660 nm
Valor Normal: <6.0% en no diabeticos
|
CATALOGO
H7541-40 R1 Latex 1 x 30 ml
R2a Buffer 1 x 9.5 ml
R2b Antibody 1 x 0.5 ml
Lyse Reagent 1 x 125 ml
H7541-120
R2a Buffer 1 x 28.5 ml
R2b Antibody 1 x 1.5 ml
|
Productos Relacionados
H7541-CAL HbA1c Calibator set
H7541-CTL HbA1c Control set
H7541-LYS HbA1c Lyse Reagent 500 ml |
_____________________________________________________________________________________________________

|
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
Direct/Automated |
ALMACENAMIENTO: 02-8°C
Estabilidad despues de reconstituir: Listo para Usarse
Linealidad:150 mg/dL
Long. Onda: 600/700 nm
Valor Normal: 30-85 mg/dL |
CATALOGO
H7545-40 1 x 30 ml (R1)
1 x 10 ml (R2)
H7545-80 1 x 60 ml (R1)
1 x 20 ml (R2)
H7545-320 1 x 240 ml (R1)
1 x 80 ml (R2)
H7545-1000 1 x 750 ml (R1)
1 x 250 ml (R2)
Requiere Standard / Calibrador |
Productos Relacionados
H7545-CAL autoHDL/LDL Calibrator
L7580-18 Lipid Control Set |
_____________________________________________________________________________________________________

|
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
2-Oxobutyrate, Kinetic |
ALMACENAMIENTO: 02-8°C
Estabilidad despues de reconstituir: 5 Dias 2-8°C
Linealidad:0-1000 U/L
Long. Onda: 340 nm
Valor Normal: 68-135 U/L |
CATALOGO
H7569-39 6 x 6.5 ml
H7569-65 10 x 6.5 ml
H7569-150 10 x 15 ml
|
|
_____________________________________________________________________________________________________

|
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
ß-Hydroxybutyrate Dehydrogenase, Endpoint |
ALMACENAMIENTO: 02-8°C
Estabilidad despues de reconstituir: Listo para usar
Linealidad:4.5 mM
Long. Onda: 505 nm
Valor Normal: 0.02 to 0.27 mM |
CATALOGO
H7587-58 Reagent 1 x 50 ml(R1)
1 x 8 ml (R2)
Standard 1 x 3 ml
|
Productos Relacionados
H7587-STD ß-Hydroxybutyrate Standard
H7587-CTL ß-Hydroxybutyrate Controls |
_____________________________________________________________________________________________________

|
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
Ferrozine, Endpoint |
ALMACENAMIENTO: 02-8°C
Estabilidad despues de reconstituir: Listo para usar
Linealidad:500 ug/dL
Long. Onda: 560 nm
Valor Normal:
Iron, Total: 60-150 ug/dL
TIBC: 250-400 ug/dL
Iron Saturation: 20-55% |
CATALOGO
I7504-60 60 test kit
Iron Buffer 2 x 75 ml
UIBC Buffer 1 x 120 ml
Iron Color 1 x 15 ml
Iron Standard 2 x 30 ml
I7504-400 400 test kit
Iron Buffer 1 x 1 L
UIBC Buffer 1 x 1 L
Iron Color 1 x 60 ml
Iron Standard 1 x 500 ml
|
Productos Relacionados
H7587-STD ß-Hydroxybutyrate Standard
H7587-CTL ß-Hydroxybutyrate Controls |
_____________________________________________________________________________________________________

|
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
Ferrozine, Endpoint |
ALMACENAMIENTO: 02-8°C
Estabilidad despues de reconstituir: Listo para usar
Linealidad:500 ug/dL
Long. Onda: 560 nm
Valor Normal:60-150 ug/dL
|
CATALOGO
I7505-120 Buffer 1 x 120 ml
Color 1 x 5 ml
I7505-500 Buffer 1 x 500 ml
Color 1 x 15 ml
Requiere Standard / Calibrador |
Productos Relacionados
I7505-STD Iron Standard
C7506-50 Chemistry Calibrator |
_____________________________________________________________________________________________________

|
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
Endpoint |
ALMACENAMIENTO: 2-8°C
Estabilidad despues de reconstituir: Listo para usar
Long. Onda: 560 nm
Valor Normal:TIBC: 250-400 ug/dL |
CATALOGO
I7506-500 1 x 500 ml
Requiere Standard / Calibrador |
Productos Relacionados
I7505-STD Iron Standard
I7505 Total Iron Reagent |
_____________________________________________________________________________________________________

|
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
Enzymatic/Colorimetric, Initial Rate |
ALMACENAMIENTO: 2-8°C
Estabilidad despues de reconstituir:4 Dias Temp. Amb. (RT)
21 Dias 2-8°C
Linealidad:600 U/L
Long. Onda: 550 nm
Valor Normal:0-62 U/L
|
CATALOGO
L7503-40 Substrate 4 x 10 ml
Substrate Buffer 2 x 21 ml
Activator 1 x 14 ml
Standard 1 x 3 ml
L7503-100 Substrate 10 x 10 ml
Substrate Buffer 1 x 105 ml
Activator 1 x 30 ml
Standard 1 x 3 ml
|
Productos Relacionados
L7503-STD Lipase Standardt |
_____________________________________________________________________________________________________

|
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
Modified Wacker/Tris, Kinetic |
ALMACENAMIENTO: 2-8°C
Estabilidad despues de reconstituir:8 Horas Temp. Amb. (RT)
21 Dias 2-8°C
Linealidad:800 IU/L
Long. Onda: 340 nm
Valor Normal:Hombre: 80-285 U/L
Mujer: 103-227 U/L
|
CATALOGO
L7535-39 6 x 6.5 ml
L7535-150 10 x 15 ml
L7535-300 20 x 15 ml
L7535-400 8 x 50 ml
L7535-1L 4 x 250 ml
|
|
_____________________________________________________________________________________________________

|
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
Modified Wacker/Tris, Kinetic |
ALMACENAMIENTO: 2-8°C
Estabilidad despues de reconstituir:Listo para usarse
Linealidad:0-1000 U/L
Long. Onda: 340 nm
Valor Normal:80-285 U/L
|
CATALOGO
L7572-150 1 x 120 ml (R1)
1 x 30 ml (R2)
L7572-450 3 x 120 ml (R1)
1 x 90 ml (R2)
L7572-625 1 x 500 ml (R1)
1 x 125 ml (R2)
|
|
_____________________________________________________________________________________________________

|
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
Direct / Automated |
ALMACENAMIENTO: 2-8°C
Estabilidad despues de reconstituir:Listo para usarse
Linealidad:0-700 mg/dl
Long. Onda: 546/660nm
Valor Normal:<130 mg/dl
|
CATALOGO
L7574-40 1 x 30 ml (R1)
1 x 10 ml (R2)
L7574-80 1 x 60 ml (R1)
1 x 20 ml (R2)
L7574-320 1 x 240 ml (R1)
1 x 80 ml (R2)
Requiere Calibrador
|
Productos Relacionados
H7545-CAL autoHDL/LDL Calibrator
L7580-18 Lipid Control Set |
_____________________________________________________________________________________________________

|
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
Lactate Oxidase, Endpoint |
ALMACENAMIENTO: 2-8°C
Estabilidad despues de reconstituir:Listo para usarse
Linealidad:0-20 mmol/L
Long. Onda: 550nm
Valor Normal:0.5-2.2 mmol/L |
CATALOGO
L7596-50 1 x 30 ml (R1)
1 x 20 ml (R2)
Requiere Standard |
Productos Relacionados
L7596-STD Lactate Standard |
_____________________________________________________________________________________________________

|
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
Immunoturbidimetric |
ALMACENAMIENTO: 2-8°C
Estabilidad despues de reconstituir:Listo para usarse
Linealidad:2-80 mg/dL
Long. Onda: 700 nm
Valor Normal:Less than 30 mg/dL |
CATALOGO
L7597- 30 1 x 20 ml (R1)
1 x 10 ml (R2)
Requiere Calibrador |
Productos Relacionados
L7597-CAL Lp(a) Calibrator Set
L7580-18 Lipid Control Set |
_____________________________________________________________________________________________________

|
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
Calmagite, Endpoint |
ALMACENAMIENTO: Temperatura Ambiente (RT)
Estabilidad despues de reconstituir:48 Horas Temperatura Amb.(RT)
Linealidad:4.86 mg/dL
Long. Onda: 530 nm
Valor Normal:1.5-2.6 mg/dL
|
CATALOGO
M7527-135 Color 1 x 120 ml
Buffer 1 x 15 ml
M7527-560 Color 1 x 500 ml
Buffer 4 x 15 ml
M7527-1120 Color 1 x 1 L
Buffer 1 x 120 ml
Requiere Standard / Calibrador |
Productos Relacionados
M7527-STD Magnesium Standard
C7506-50 Chemistry Calibrator |
_____________________________________________________________________________________________________

|
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
Immunoturbidimetric |
ALMACENAMIENTO: 2-8°C
Estabilidad despues de reconstituir:Listo para Usarse
Linealidad:0.5-30.0 mg/dL
Long. Onda: 340 nm
Valor Normal:Less than 2.1 mg/dL
(24 horas) |
CATALOGO
M7562-100 Buffer 4 x 20 ml
Antiserum 2 x 10 ml
Requiere Set Calibrador |
Productos Relacionados
M7562-CAL Microalbumin Calibrator Set
M7562-CTL Microalbumin Control Set |
_____________________________________________________________________________________________________

|
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
Phosphomolybdate, Endpoint |
ALMACENAMIENTO: 2-8°C
Estabilidad despues de reconstituir:Listo para Usarse
Linealidad:12 mg/dL
Long. Onda: 340 nm
Valor Normal:2.5-4.8 mg/dL |
CATALOGO
P7516-120 1 x 120 ml
P7516-500 1 x 500 ml
P7516-1L 1 x 1 L
Requiere Calibrador / Standard |
Productos Relacionados
P7516-STD Phosphorus Standard
C7506-50 Chemistry Calibrator |
_____________________________________________________________________________________________________

|
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
Sodium Tetraphenylboron, Turbidimetric |
ALMACENAMIENTO:Temperatura Ambiente
Estabilidad despues de reconstituir:8 Hours Temperatura Amb. (RT)
Calibrador: 14 Dias 2-8°C
Linealidad:2-6.5 mEq/L
Long. Onda: 630 nm
Valor Normal:3.4-5.3 mEq/L
|
CATALOGO
P7520-120 Reagent 1 x 120 ml
Calibrator 1 x 5 ml
Activator 1 x 4 ml
|
Productos Relacionados
C7506-50 Chemistry Calibrator |
_____________________________________________________________________________________________________

|
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
Pyrogallol Red, Endpoint |
ALMACENAMIENTO:2-8°C
Estabilidad despues de reconstituir:Listo para Usarse
Linealidad:250 mg/dL
Long. Onda: 600 nm
Valor Normal:28-141 mg
(24 horas) |
CATALOGO
P7582-240 Reagent 2 x 120 ml
Standard 1 x 15 ml
|
Productos Relacionados
P7582-STD Microprotein Standard
P7582-CTL Urine Chemistry Controls |
_____________________________________________________________________________________________________

|
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
Biuret, Endpoint |
ALMACENAMIENTO:Temp. Amb.
Estabilidad despues de reconstituir:Listo para Usarse
Linealidad:1.0-15.0 g/dL
Long. Onda: 540 nm
Valor Normal:6.2-8.5 g/dL |
CATALOGO
T7528-120 1 x 120 ml
T7528-500 1 x 500 ml
T7528-1L 1 x 1 L
Requiere Calibrador / Standard |
Productos Relacionados
T7528-STD Protein Standard
C7506-50 Chemistry Calibrator |
_____________________________________________________________________________________________________

|
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
Enzymatic/GPO Trinder, Endpoint |
ALMACENAMIENTO:2-8°C
Estabilidad despues de reconstituir:2 Dias RT
30 Dias 2-8°C
Linealidad:1000 mg/dL
Long. Onda: 540 nm
Valor Normal:36-165 mg/dL |
CATALOGO
T7531-75 5 x 15 ml
T7531-150 10 x 15 ml
T7531-300 20 x 15 ml
T7531-400 8 x 50 ml
T7531-1L 4 x 250 ml
Requiere Calibrador / Standard |
Productos Relacionados
T7531-STD Triglyceride Standard
C7506-50 Chemistry Calibrator
L7580-18 Lipid Control Set |
_____________________________________________________________________________________________________

|
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
Enzymatic/GPO Trinder, Endpoint |
ALMACENAMIENTO:2-8°C
Estabilidad despues de reconstituir:Listo para Usarse
Linealidad:1000 mg/dL
Long. Onda: 500 nm
Valor Normal:44-148 mg/dL |
CATALOGO
T7532-120 1 x 120 ml
T7532-500 1 x 500 ml
T7532-1L 1 x 1 L
Requiere Calibrador / Standard |
Productos Relacionados
T7531-STD Triglyceride Standard
C7506-50 Chemistry Calibrator
L7580-18 Lipid Control Set |
_____________________________________________________________________________________________________

|
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
Uricase/Trinder, Endpoint |
ALMACENAMIENTO:2-8°C
Estabilidad despues de reconstituir:48 Horas Temperatura Amb.(RT)
31 Days 2-8°C
Linealidad:25 mg/dL
Long. Onda: 520 nm
Valor Normal:2.5-7.7 mg/dL |
CATALOGO
U7580-150 10 x 15 ml
U7580-300 20 x 15 ml
U7580-400 8 x 50 ml
U7580-1L 4 x 250 ml
Requiere Calibrador / Standard |
Productos Relacionados
U7580-STD Uric Acid Standard
C7506-50 Chemistry Calibrator |
_____________________________________________________________________________________________________

|
_______________________________________________________
METODO |
INFORMACION TECNICA |
PRESENTACION |
Uricase/Trinder, Endpoint |
ALMACENAMIENTO:2-8°C
Estabilidad despues de reconstituir:Listo para Usarse
Linealidad:20 mg/dL
Long. Onda: 520 nm
Valor Normal:2.5-7.7 mg/dL |
CATALOGO
U7581-120 1 x 120 ml
U7581-500 1 x 500 ml
U7581-1L 1 x 1 L
Requiere Calibrador / Standard |
Productos Relacionados
U7580-STD Uric Acid Standard
C7506-50 Chemistry Calibrator |
Inicio | | | Hematología |Quimica Clinica| Unico| | Contactenos | |
|
 |
| |
|
 |
|
|
|